Sika Ucrete · Polyurethane cement flooring · Saudi Arabia

Ucrete flooring for Saudi kitchens, food plants and cold rooms

Ucrete is Sika’s polyurethane cement flooring range for demanding process environments. Selecting a floor starts with the room’s temperature changes, chemicals, traffic and cleaning routine, then the exact grade, thickness and detailing. SolidDrops supports project enquiries across Saudi Arabia.

Send your room schedule, approximate area and operating conditions for a scoped Ucrete enquiry. A freezer entrance, a cooking line and a dry packing hall may need different specifications within the same building.

What is Ucrete, and who makes it now?

Current manufacturer documents identify the range as Sika® Ucrete®. Older specifications and packaging may refer to Ucrete under Master Builders Solutions. Use the current Sika product name and the product data sheet applicable to the project; a legacy name alone does not establish that two proposed materials have the same specification.

Ucrete is a resin-and-cement flooring family, rather than a generic name for every polyurethane screed. Sikafloor PurCem, Mapefloor CPU and other polyurethane cement systems must be assessed on their own documentation. Substitution requires a comparison of the complete build-up and the project’s acceptance criteria.

Manufacturer reference: Sika GCC Ucrete range. The Sika regional rebranding notice provides background on the transition.

Define exposure before asking for a price. Record the highest discharge temperature, lowest operating temperature, wet or dry traffic, chemical concentrations and available shutdown. “Food-grade flooring” or “9 mm PU” alone is not a complete specification.
Commercial kitchen with a grey floor, stainless-steel work areas and floor drains
Kitchen layout illustration showing why drainage and cleanable interfaces belong in the floor brief. Product and project identity require confirmation.

Compare Ucrete grades by the job they need to do

These are selection starting points. Manufacturer values relate to a named product and test conditions, and do not promise the same result for every floor. Confirm the current local data sheet, system components and proposed application before approval.

On small screens, each table row is shown as a labelled card.

Ucrete grades already referenced in the SolidDrops range
Grade or componentSelection starting pointEvidence and qualification
Sika Ucrete UD 200Textured heavy-duty screed for wet or dry process areas where traffic and thermal exposure need reviewGCC PDS lists 6, 9 and 12 mm options. The temperature limits are thickness-specific; see the table below
Sika Ucrete MFSmooth finish for dry packing, storage, warehouses and appropriate clean-room areasGCC PDS gives approximately 4–6 mm. Its −15°C to +70°C service range is stated for 6 mm
Sika Ucrete HF 60 RTFlow-applied, lightly textured option for large wet or dry process areasGCC PDS describes a 6 mm screed and a −25°C to +80°C service range
Sika Ucrete HF 100 RTFlow-applied, lightly textured option where a 9 mm build-up is being consideredCurrent UK manufacturer information confirms this product. Obtain the applicable Saudi/GCC submittal before specifying local performance or availability
Sika Ucrete DP10, DP20 and DP30Profiled systems to discuss where contamination, traction and cleanability need balancingThe exact DP designation, thickness and component schedule matter. The UK DP10 4 mm sheet is an example, not approval for every DP system or Saudi project
Sika Ucrete RGRender and coving mortar for compatible upstands, skirting, plinths and drainage detailsConfirmed in the current GCC range. Specify the vertical detail separately from the floor wearing layer
Sika Ucrete CR 460Joint filler for appropriate resin-floor joints and details around channels or gulliesUse with its specified primer and joint design. It is a complementary joint product, not a floor screed
Antistatic grades; TZ, IF and HPQ referencesSpecialist or legacy specification enquiriesSend the full designation. MF 40 AS appears in the GCC range; other legacy names need current local confirmation rather than assumed equivalence
Smooth and textured resin-floor sample pieces beside a coved sample
Finish-selection illustration. Approve physical samples of the specified system before installation.

UD 200 temperature limits depend on thickness

On small screens, each table row is shown as a labelled card.

Sika GCC UD 200 PDS, July 2024, version 03.01, accessed 5 October 2026
ThicknessMinimumMaximum listed service temperatureOccasional spillage
6 mm−25°C+80°CNo separate higher value listed
9 mm−40°C+120°CNo separate higher value listed
12 mm−40°C+130°CUp to +150°C

Do not apply the +150°C occasional-spillage figure to 6 mm or 9 mm installations, or treat it as a universal operating temperature. The frequency, duration and location of discharge also belong in the review.

Check the current manufacturer pages for UD 200, MF, HF 60 RT, RG, HF 100 RT (UK) and DP10 4 mm (UK).

Match the floor to each room

Grey floor with a channel drain beside cold-room doors and storage racks
Cold-room illustration. Coordinate thresholds, drainage, thermal exposure and the selected floor build-up.

Kitchens and wet food production

Map cook lines, dishwashing, oil and grease, hot discharge, trolley paths and drain locations. Review a textured grade, cove details and cleaning access together. A surface sample helps the facilities team judge the finish before a large area is committed.

Cold rooms and freezer thresholds

Provide the operating and defrost cycle, adjacent room temperature and threshold detail. Check insulation, slab movement and moisture at transitions. A low-temperature material rating does not by itself resolve a floor’s thermal design.

Dairy, juice and beverage rooms

Identify the actual process and cleaning chemicals, including concentration and temperature. Note repeated spill locations and cleaning-in-place discharge. Request confirmation of chemical compatibility for the selected floor and joint materials.

Meat, poultry and seafood processing

Discuss wet contamination, wheeled loads, falls, drain covers and the cleaning routine. Separate product-selection requirements from operational hygiene controls and the facility’s own food-safety approval process.

Bakeries and dry packing halls

Distinguish dry circulation from washdown, oven-side and mixing areas. A smoother option may be worth assessing where the room remains dry, while adjoining wet areas can call for a different finish.

Pharmaceutical and chemical facilities

Provide the room classification, cleaning agents, containment duty and any static-control requirement. A standard resin floor is not automatically an ESD system or a certified clean-room installation.

اقرأ عن أرضيات يوكريت بالعربية. For a facility-wide comparison, see our food-processing floor selection guide.

Saudi site conditions: check the slab, room and stored materials

High service-temperature resistance is different from permission to install into a hot room. Measure the substrate, ambient air and material temperatures separately. Plan protected storage, ventilation, enclosure and a workable installation period against the chosen grade’s current limits.

For example, the reviewed UD 200 GCC PDS lists ambient air at +5°C to +25°C, while the material and substrate minima are +10°C. Those are not one shared +5°C application limit. Other grades have different windows; do not transfer a limit from a UK document or another Ucrete product without confirmation.

  • Concrete and existing finishes: assess soundness, contamination, moisture, cracks, laitance and old coatings before agreeing preparation or overlay work
  • Edges and movement: detail terminations, movement joints, thresholds and any required anchoring in the project method statement
  • Wet-area interfaces: coordinate falls, drain heights, coves, wall linings and penetrations with the other trades
  • Condensation and leaks: manage dripping pipework, adjacent cold zones and early water exposure
  • Appearance: agree colour and texture from samples, including any expected UV-related colour change described by the manufacturer

A resin wearing surface should not be assumed to replace a separately required waterproofing design. Review the floor-to-wall and drainage build-up as a complete assembly.

Installation planning, from survey to handover

Workers trowelling a grey floor beside a coved wall junction and drain
Installation illustration showing the floor, cove and drain interfaces. Follow the approved system detail and method statement.

Sika’s reviewed GCC documents require application by a trained and licensed Ucrete applicator. Confirm the proposed installation party and include its current credentials in the technical submittal.

  1. Survey and agree the exposure schedule. Identify room zones, existing defects, traffic, cleaning and the operating temperatures that drive selection.
  2. Approve the system and interfaces. Record the exact grade, thickness, finish, compatible components, movement joints, coves, drains and acceptance requirements.
  3. Prepare and inspect the substrate. Complete the specified mechanical preparation and repairs; document the agreed checks before covering the slab.
  4. Install to the approved method. Control batches, mixing, environmental conditions, build-up and edge detailing. This overview does not replace the manufacturer’s instructions.
  5. Protect and release the area. Agree separate release criteria for pedestrian traffic, wheeled loads, cleaning and process exposure. The earliest traffic time is not an unconditional full-service promise.
  6. Hand over the maintenance information. Include the installed-system record, cleaning limits, inspection points and the process for reporting damage.

Common specification gaps to resolve early

An unprepared slab, an assumed tile overlay, the wrong thickness for hot discharge, a feathered termination or premature washdown can undermine a project. Address the cause and the interface detail rather than choosing the product from a single headline strength or temperature figure.

Ucrete or epoxy: compare the operating conditions

Both choices cover multiple systems. Compare the actual proposed epoxy build-up with the actual Ucrete grade, using chemical exposure, thermal cycling, traffic, texture, downtime and whole-project cost. It is misleading to compare every epoxy floor with one thin coating, or to assume every polyurethane cement grade tolerates steam cleaning.

A dry warehouse, decorative interior and wet cooking area can have different priorities. Start with SolidDrops’ epoxy flooring guidance for general resin-floor enquiries, and use this page for the specific Sika Ucrete decision.

Prepare a useful consultant specification

State the room use, substrate acceptance criteria, exact system designation, nominal thickness, slip-test requirement, chemical exposure schedule and thermal duty. Add details for coves, joints, drains and terminations, then identify inspection hold points, a sample area and handover requirements. Request the current local PDS, component SDS, method statement and any relevant test reports as a coordinated submittal.

Cleaning and maintenance

Agree the detergent, dilution, cleaning temperature, equipment and rinsing procedure with the system supplier and facilities team. Inspect joints, drains and transitions, remove residues promptly and investigate damage before it spreads. Material-level hygiene or emissions documentation does not replace cleaning, safe working practices or the facility’s own approvals.

Ucrete flooring questions

Is Ucrete suitable for an industrial kitchen?

It is a candidate for demanding food-production environments. Select the exact grade and thickness against hot discharge, chemicals, wet traffic, drainage and cleaning. The room name alone is not enough to approve a system.

Can Ucrete be used in a freezer?

Some specified grades and thicknesses cover low-temperature service. Check the exact manufacturer rating alongside the slab, insulation, defrost and threshold design before selecting a floor.

How much does Ucrete flooring cost in Saudi Arabia?

A useful quotation needs the area, grade, thickness, preparation, repairs, cove length, drain and joint details, access and programme. Separate these items in the scope so that quotations cover the same work. Current material price and availability must be confirmed for the enquiry.

How quickly can the area reopen?

Confirm the release plan for the selected grade and actual site conditions. Published cure or traffic times are conditional; cleaning, chemicals and heavy operations may need separate approval. Include preparation and repairs in the shutdown plan.

Can it be installed over tiles or an old coating?

Do not assume an overlay is acceptable. Assess adhesion, contamination, moisture, levels and the underlying substrate, then obtain an approved preparation and build-up. The survey may identify removal or repair work.

What do HACCP, Halal or emissions references mean?

The reviewed Sika GCC pages list specific reports and certificates for named Ucrete materials. Request the relevant current documents and check their scope against the product and intended application. They do not automatically certify SolidDrops, an installer or the whole facility.

What if our BOQ uses an older Ucrete name?

Send the full product name and existing technical submittal. Confirm its current Sika designation and regional documentation before proposing a substitution or ordering components.

A short Ucrete specification glossary

PU cement
A polyurethane-and-cement material family; the exact system still needs to be named.
Cove
A curved floor-to-wall transition detailed to suit the adjoining finishes and cleaning requirement.
Thermal cycling
Repeated temperature changes; record both extremes and how quickly they occur.
Slip profile
The surface texture selected for the contamination, footwear and cleaning regime, supported by an agreed test requirement.
Return to traffic
A stated stage of cure under defined conditions, distinct from an unrestricted process restart.

Send a Ucrete project brief to SolidDrops

SolidDrops serves projects across Saudi Arabia, including Riyadh, Jeddah, Dammam, Jubail, Makkah, Madinah and Tabuk. Include the city and access requirements so the scope and programme can be reviewed.

  • Facility and room use, approximate area in m² and target handover date
  • Drawings, BOQ, site photos and existing floor condition
  • Highest discharge and lowest operating temperatures, including cleaning and defrost cycles
  • Chemical names, concentration, contact time, traffic and cleaning method
  • Drain, cove, joint, texture, colour and any ESD requirements

Call +966 50 213 1112 or use the SolidDrops contact page.

WhatsApp contact iconChat Online
1

What we need to recommend the right Ucrete or PU cement floor

Best suited forIndustrial kitchens, food factories, wet processing areas, cold rooms and hot-washdown zones.
System selection checksTemperature, chemicals, cleaning method, drainage, slip profile, impact, substrate and shutdown window.
For a faster quotationSend the city, approximate area, photos, drawings or BOQ, current condition and required completion date.
Start Ucrete and PU cement flooring enquiry WhatsApp project details