Synergy systems · supplied & installed across KSA

Fire Suppression Systems in Saudi Arabia for Commercial Kitchens and Electrical Panels

Documents needed for system review

  • Identify the protected hazard and the exact manufacturer and model proposed in the project specification.
  • Provide drawings, design criteria and the required authority or consultant approvals for review.
  • Detection, controls, agent discharge and maintenance requirements must follow the selected system manual; product families are not interchangeable.

SolidDrops supplies and installs two Synergy fire suppression systems in Saudi Arabia: the UL Listed wet-chemical Kitchen Fire Suppression System for hoods, appliances and ducts, and the LPCB-approved Firessense direct low-pressure clean-agent system for electrical panels and enclosures. Neither needs external power to discharge.

  • UL Listed kitchen system
  • LPCB · LPS 1666 Firessense
  • No external power
  • Survey → install → commission
Synergy Firessense clean-agent cylinder and red detection tube installed on an electrical control panel
Synergy automatic kitchen fire suppression activation panel with UL Listed label and pull handle
Real Synergy equipment: Firessense on a control panel, and the UL Listed kitchen activation panel.
  • UL ListedSynergy wet-chemical kitchen system
  • LPCB · LPS 1666Synergy Firessense panel system
  • ISO 9001 & 45001Manufacturer certifications
  • 7 cities +Survey and install across KSA
Start with the hazard

Which fire suppression system does your project need?

A fire suppression system is a fixed installation that detects a fire at a defined hazard and discharges an extinguishing agent onto it automatically, without waiting for someone to reach an extinguisher. In Arabic specifications it usually appears as نظام إطفاء الحريق التلقائي. The right system depends on what is burning: hot cooking oil in a kitchen hood behaves nothing like an overheating busbar inside a switchgear panel, and each needs a different agent, a different detector and a different discharge path.

Synergy kitchen fire suppression system discharging wet chemical over a fryer, range and wok under a commercial hood

Kitchens · Wet chemical

Synergy Kitchen Fire Suppression System

For restaurants, hotel kitchens, hospital and central kitchens, food courts and cloud kitchens. It protects the cooking appliances, the hood plenum and the exhaust duct as one design, and shuts off the fuel at the same moment it discharges.

  • UL Listed wet-chemical system
  • Fusible-link detection plus a manual pull station
  • Shuts off gas, stops the fan, sounds the alarm
  • K-class stainless steel cylinders from 9 to 30 litres

Kitchen hood fire suppression system in Saudi Arabia →

Firessense red fire detection tube routed across breakers inside an electrical cabinet

Panels · Clean agent

Synergy Firessense Direct Low-Pressure System

For switchgear and control panels, data and telecom cabinets, UPS, generator and transformer enclosures, CNC machines and lab cabinets. It protects the inside of the enclosure where a fault starts, not the whole room.

  • LPCB approved, LPS 1666 certified
  • FK-5-1-12 or HFC-227ea clean agent, no residue
  • Detection tube runs inside the enclosure
  • 1, 2 and 4 kg cylinders; −20 °C to +60 °C

Electrical panel fire suppression system in Saudi Arabia →

Side by side

Kitchen vs panel fire suppression: key facts

Both systems are manufactured by Swastik Synergy Engineering Pvt. Ltd. at Khopoli near Mumbai; the company holds ISO 9001:2015 and ISO 45001:2018 and is CCOE (PESO) approved for filling and storing clean agent gases. SolidDrops is the supplier and installer in Saudi Arabia. Every figure below comes from the manufacturer’s product data.

Property Synergy Kitchen System Synergy Firessense
Protected hazard Cooking appliances, hood plenum and exhaust duct Inside of an electrical or equipment enclosure
Agent Low-pH wet chemical, light brown liquid, SG 1.02–1.05 g/cm³ FK-5-1-12 or HFC-227ea (NFPA 2001 clean agents)
Approval UL Listed; developed to NFPA and UL standards LPCB approved; LPS 1666 certified
Design basis NFPA and UL standards NFPA 2001, LPS 1666, NBC 2016
Detection Fixed-temperature fusible links on tensioned wire, plus manual pull station Fire detection tube routed through the enclosure
Actuation & power Mechanical, via CO2 cartridge; no external power Stored pressure 15 bar at 21 °C; no external power
Cylinders 9, 12, 15, 18, 21, 24, 27, 30 L, K-class stainless steel 1 kg (Ø85 × 255 mm), 2 kg (Ø110 × 300 mm), 4 kg (Ø140 × 400 mm)
Temperature Agent freeze point −7 °C Rated −20 °C to +60 °C
Interlocks Fan stop, gas or electrical cut-off, optional gas shut-off valve, audio-visual alarm Pressure switch to monitoring panel
After discharge Soap-like foam layer on the hot grease; no toxic vapours No residue; non-toxic on discharge
Comparison graphic of Synergy kitchen wet-chemical and Firessense electrical panel clean-agent fire suppression systems
Two hazards, two agents. Choose by what is burning, not by the size of the room.
Commercial kitchens

How does a kitchen hood fire suppression system work?

A kitchen hood fire suppression system is a pre-piped wet-chemical system that discharges over the cooking line and into the hood and duct the moment a fusible link melts. Grease fires are the reason it exists. Water on burning oil throws the fire out of the pan, a dry-powder extinguisher knocks the flame down without cooling the oil, and a fryer that has been running through lunch service can re-ignite minutes after the visible flame is gone.

The Synergy system is designed around that behaviour. Its nozzles are positioned for each appliance, for the plenum behind the filters and for the exhaust duct, because a hood fire rarely stays on the cooktop: burning grease is drawn up through the filters into the duct, where it is hardest to reach by hand. The wet chemical cools the oil and lays a soap-like blanket on the surface, a reaction known as saponification, which is what stops re-ignition.

Everything is mechanical. Detection, actuation and discharge do not depend on mains power, so a fire that trips the kitchen’s electrical supply cannot stop the system from working.

Synergy kitchen fire suppression system layout showing cylinder, activation panel, fusible links, nozzles over fryer, range and wok, and gas shut-off valve
Synergy layout: cylinder and activation panel, fusible links in the hood, nozzles over each appliance, and the gas shut-off valve.
  1. DetectFusible links on a tensioned wire sit in the hood and duct. When one reaches its rated temperature it releases, and a staff member can also trigger the system from the manual pull station.
  2. ActuateThe automatic mechanical activation panel fires a CO2 cartridge that pressurises the agent cylinder. Nothing depends on mains power.
  3. SuppressThe low-pH wet chemical sprays through nozzles aimed at each appliance, the plenum and the duct, cooling the oil and sealing its surface under a foam layer.
  4. IsolateThe system shuts the gas or electrical supply to the cooking line, stops the exhaust fan and sounds the audio-visual alarm, so the fire is not fed while staff leave.
Infographic showing the four stages of a wet-chemical kitchen fire suppression system: detect, actuate, suppress and isolate
The four stages of a Synergy kitchen discharge.
Changing the cooking line? Moving a fryer, adding a chargrill or swapping a range for a wok station changes nozzle coverage. Tell us before the equipment moves, and keep the separate hood and duct cleaning schedule going; suppression is not a substitute for clean filters.
What gets installed in your kitchen

Synergy kitchen fire suppression system components

A complete Synergy kitchen installation is built from ten components. Knowing them helps when you compare quotations: an offer that lists a cylinder and nozzles but leaves out the gas shut-off valve or the pull station is not the same system.

All ten components

  1. Cylinder with valve and pressure gauge
  2. Activation relay unit
  3. Audio-visual alarm
  4. Automatic mechanical activation panel
  5. Corner pulley
  6. Fusible link bracket
  7. Fusible link
  8. Nozzle
  9. Manual activation pull station
  10. Gas shut-off valve

Choosing the cylinder size

Eight cylinder sizes, from 9 to 30 litres, let the agent quantity match the cooking line rather than rounding up to the next big tank. The size and the number of cylinders depend on how many appliances sit under the hood, what type they are, and the length of hood and duct the nozzles must cover. We calculate it from your appliance schedule during design, which is why a list of the appliances is the most useful thing you can send with an enquiry.

Electrical and equipment enclosures

How Firessense protects an electrical panel

Firessense is a direct low-pressure system: a heat-sensitive detection tube is routed through the hottest parts of the enclosure, close to the busbars, breakers or drives most likely to fail. A fire at any point on the tube makes it burst at that spot, and the agent discharges from the cylinder straight through the opening into the enclosure. In a direct system the tube is both the detector and the discharge point, so there are no separate nozzles to position and no external power or control panel needed to fire it.

The agent is either FK-5-1-12 or HFC-227ea. HFC-227ea is the clean agent widely known by the trade name FM-200, which is why consultants often specify panel protection as “FM-200 type”. Both are electrically non-conductive, leave no residue on circuit boards and are non-toxic on discharge, so equipment can be inspected and returned to service without a clean-up of powder or water.

The cylinder is sized to the internal volume and layout of each enclosure from the manufacturer’s design data; that is why we ask for panel dimensions before we quote. A pressure switch reports the discharge to a monitoring panel, and the system is rated for −20 °C to +60 °C, which matters inside sealed panels in a Riyadh or Dammam summer. We check the internal ambient of the enclosure before installation.

Firessense system configuration showing clean-agent cylinder, detection tube through electrical panels, pressure switch and monitoring panel
Firessense configuration: cylinder, detection tube through the panels, pressure switch and monitoring panel.

Also in the installation: the cylinder valve, mounting bracket, tee and in-line connectors, and the end-of-line plug with Schrader valve used to check the tube pressure.

Where these systems are used

Fire suppression applications in Saudi Arabia

The kitchen system covers any commercial cooking line under a hood: restaurants and cafés, hotel and banqueting kitchens, hospital and university kitchens, central production kitchens, food courts and cloud kitchens. Firessense covers the ten enclosure types the manufacturer lists, shown below.

Electrical control panel protected by Firessense
Electrical & control panels
Data centre server racks, an application for Firessense
Data centre server racks
UPS units in a power room
UPS & battery cabinets
Diesel generator set enclosure
Generator enclosures
Transformer cabinet with door open
Transformer cabinets
Telecommunication tower and shelter equipment
Telecom shelters
Pump enclosure at an industrial site
Pump enclosures
CNC and VMC machining centre
CNC & VMC machines
Laboratory fume cabinets
Lab fume cabinets
Flammable chemical storage cabinet
Flammable storage cabinets
Why fires start

Fire risks in Saudi kitchens and switch rooms

Most kitchen and panel fires are not dramatic events. They start from conditions that build up quietly over months, which is why automatic protection at the source matters more than an extinguisher on the wall.

Hotel and restaurant kitchens in Makkah and Madinah run at very high cooking volumes during Hajj and Ramadan, and data and power rooms across the Kingdom carry their heaviest cooling load through the summer. Plan installations and service visits before those peaks, not during them.

  • Grease in filters and ductsDeposits build up behind the filters and inside the duct, where a flare-up on the cooktop can spread out of reach.
  • High-volume fryingOil held at temperature for hours is close to its ignition point; one overheated fryer is enough.
  • Loose terminationsA loose cable lug or breaker connection heats up under load long before anyone notices.
  • Heat and dust in panelsSealed enclosures run hot in summer, and dust on boards and busbars adds fuel and tracking paths.
Documents for your consultant

Approvals and documentation for fire suppression in Saudi Arabia

On Saudi projects the fire suppression submittal is reviewed by the project consultant and, through the building’s fire safety approval, by the General Directorate of Civil Defense (المديرية العامة للدفاع المدني) under the Saudi Fire Code, SBC 801. Approval moves faster when the listing and design documents match the exact configuration being installed, so we prepare the submittal around your drawings rather than sending a generic brochure.

Kitchen system pack

UL listing documentation for the Synergy Kitchen Fire Suppression System, the cylinder and nozzle layout for your appliance schedule, interlock wiring for gas and fan shut-down, and the component data sheets.

Firessense pack

LPCB approval and LPS 1666 certification evidence, the cylinder selection for each enclosure volume, detection tube routing, and the pressure-switch and monitoring interface.

Handover pack

The commissioning record, as-installed layout, operating instructions for kitchen or facilities staff, and the service requirements for the installed configuration.

For kitchen ventilation and grease-duct design, NFPA 96 is the usual reference for the wider project team. Where your consultant names a specific edition or local requirement, send it with the enquiry and we will check the offered system against it before quoting.

How a project runs

Fire suppression installation: from survey to handover

Kitchen work is usually planned around trading hours and a gas shutdown window; panel work around a power shutdown. The sequence is the same for both.

  1. Site surveyFor kitchens, the appliance schedule, hood and duct route. For panels, enclosure dimensions, openings, layout and internal ambient.
  2. System designCylinder size and count, nozzle or tube layout, and the interlocks your fire strategy calls for.
  3. SupplySynergy equipment delivered to site with the documentation pack for consultant review.
  4. InstallationOur team installs the pipework, nozzles, fusible links or detection tube, cylinders and pull station to the approved layout.
  5. IntegrationGas or electrical shut-off, fan stop, alarm and monitoring signals connected and checked.
  6. Commissioning & serviceFunctional checks without uncontrolled discharge, staff walkthrough, handover record, then planned servicing.
After handover

Inspection, servicing and recharge

A suppression system only works if it is still matched to the hazard it was designed for. NFPA 96 calls for commercial-kitchen fire-extinguishing systems to be serviced by trained, qualified people at least every six months, and the Synergy manuals set the detailed checks and replacement intervals for each component. Panels change too: added breakers, new cable entries or a door left open change the enclosure the Firessense cylinder was sized for.

After any discharge, the system is out of service until it is recharged. That means cleaning the agent from the cooking line, refilling or replacing the cylinder, replacing the fusible links and cartridge on a kitchen system or the detection tube on Firessense, and recording the return to service. Cooking should not restart under an unprotected hood.

What a service visit checks

  • Cylinder pressure gauge and seals
  • Fusible links and wire tension in the hood and duct
  • Nozzle positions against the current appliance layout
  • Pull station access and labelling
  • Gas shut-off and fan-stop interlocks
  • Firessense tube condition, pressure and routing
  • Pressure switch signal to the monitoring panel
  • Service tag and record updated
Budgeting

How much does a fire suppression system cost in Saudi Arabia?

There is no honest single price for a fire suppression system, because the cylinder is only one line of the quotation. A kitchen with a single 3-metre hood over two fryers needs a very different system from a hotel kitchen with a chargrill line and a long duct run, and a single control panel is a different job from a row of twelve. What we can tell you is what moves the number, so you can compare quotations on the same basis:

Cost driver Kitchen system Firessense panel system
Size of the hazard Number and type of appliances, hood length, duct length Internal volume of each enclosure, number of enclosures
Equipment Cylinder size (9–30 L) and count, nozzles, fusible links Cylinder size (1, 2 or 4 kg) per enclosure, tube length
Interlocks Gas shut-off valve, fan stop, alarm wiring Pressure switch and monitoring panel connection
Site work New build or retrofit over a working kitchen; access and shutdown window Panel shutdown window, access inside live switch rooms
Documentation Consultant submittal, commissioning record, handover and the agreed service plan

When you compare two offers, check that both cover the same appliances or enclosures, name the manufacturer and approval, and state whether installation, interlocks, commissioning and transport are included. The cheapest quotation is often the one that left the gas shut-off valve out.

Who we work with

One contractor from survey to service

  • Consultants: a submittal built on UL and LPCB documentation for the exact configuration
  • MEP and fit-out contractors: supply and installation as a defined package with clear interfaces
  • Restaurant groups and hotels: retrofits planned around trading hours, and service after handover
  • Facility managers and plant owners: panel protection without flooding the room or stopping production
  • Kitchen fit-out support from the same team: commercial kitchen epoxy flooring and hygienic FRP wall panels, plus detection from our fire alarm systems range
Kingdom-wide

Fire suppression installers in Jeddah, Riyadh, Dammam and across KSA

Our base is in the Western Region and we take survey and installation work across the Kingdom. Send the city and a photo; we will tell you the survey date and lead time for that location. The phone line is answered 24/7.

  • Jeddahجدة
  • Riyadhالرياض
  • Dammam & Khobarالدمام
  • Jubailالجبيل
  • Makkahمكة
  • Madinahالمدينة
  • Tabukتبوك
Questions buyers ask

Fire suppression system FAQs

Which fire suppression systems does SolidDrops supply in Saudi Arabia?

SolidDrops supplies and installs two Synergy systems: the UL Listed wet-chemical Kitchen Fire Suppression System for commercial hoods, appliances and ducts, and the LPCB-approved Firessense direct low-pressure clean-agent system for electrical panels and equipment enclosures. We do not supply room-flooding, sprinkler or CO2 systems.

How much does a kitchen fire suppression system cost in Saudi Arabia?

The price depends on the number and type of appliances, the hood and duct length, the cylinder size between 9 and 30 litres, the gas and fan interlocks, and whether the kitchen is new or already operating. Send the appliance list and a photo of the hood on WhatsApp and we will quote for that specific kitchen.

Is the Synergy kitchen fire suppression system UL listed?

Yes. The Synergy Kitchen Fire Suppression System is a UL Listed wet-chemical system developed to NFPA and UL standards. We provide the manufacturer’s UL documentation with the submittal so your consultant and the approving authority can check it against the installed configuration.

Does Firessense use FM-200?

Firessense uses either FK-5-1-12 or HFC-227ea. HFC-227ea is the clean agent widely sold under the FM-200 trade name. Both are NFPA 2001 clean agents, are non-conductive, leave no residue and are non-toxic on discharge, which is why they suit live electrical panels and electronics.

Do these fire suppression systems work during a power cut?

Yes. The kitchen system actuates mechanically through fusible links and a CO2 cartridge, and Firessense discharges from its own stored pressure when the detection tube bursts. Neither depends on external power, so a fire that knocks out the electrical supply cannot stop the discharge.

Can you install a kitchen suppression system on an existing hood?

Yes. We survey the existing hood, appliances and duct, then plan the installation around your opening hours and a gas shutdown window. Send photos of the hood, the appliance line and any existing system labels so we can see what has to change.

How often should a kitchen fire suppression system be serviced?

NFPA 96 calls for commercial-kitchen fire-extinguishing systems to be serviced by trained, qualified people at least every six months. The Synergy manuals set the detailed checks and component replacement intervals. The system should also be reviewed whenever an appliance is moved, added or replaced.

What happens after the system discharges?

The system is out of service until it is recharged. The agent is cleaned from the cooking line, the cylinder is refilled or replaced, the fusible links and cartridge are replaced on a kitchen system or the detection tube on Firessense, and the return to service is recorded. Do not restart cooking under an unprotected hood.

Is the wet chemical agent safe for kitchen staff?

The Synergy agent is a low-pH wet chemical that gives off no toxic vapours on discharge. Staff should still leave the kitchen when the alarm sounds, because the fire itself produces smoke and heat, and the cooking line must be cleaned before it is used again.

Can Firessense protect a whole switch room?

No. Firessense protects the inside of each enclosure where the detection tube runs. Room-level detection and protection are designed separately as part of the building’s fire strategy. Many projects use Firessense for the critical panels alongside the room’s fire alarm system.

What do I need to send for a fire suppression quotation?

Start with three things: the city, whether it is a kitchen hood or an electrical panel, and a photograph. For kitchens add the appliance list and hood length; for panels add the enclosure dimensions and how many there are. Drawings and a BOQ help but are not needed to start.

Which cities in Saudi Arabia do you cover?

We survey and install across the Kingdom, including Jeddah, Riyadh, Dammam and Khobar, Jubail, Makkah, Madinah and Tabuk. Send your city with the enquiry and we will confirm the survey date and lead time.

Terms you will see in submittals

Fire suppression glossary

Wet chemical agent
A liquid extinguishing agent for commercial cooking fires that cools hot oil and forms a soap-like layer on its surface.
Saponification
The reaction between a wet chemical agent and hot cooking fat that produces the foam layer which prevents re-ignition.
Fusible link
A fixed-temperature heat detector that separates at its rated temperature and releases the system’s actuation mechanism.
Plenum
The space behind the grease filters of a kitchen hood, between the filters and the exhaust duct.
Manual pull station
A hand-operated release that lets staff discharge a kitchen suppression system without waiting for detection.
Clean agent
A gaseous extinguishing agent that is electrically non-conductive and leaves no residue, covered by NFPA 2001.
HFC-227ea
A clean agent widely known by the trade name FM-200, used in Firessense for enclosure protection.
FK-5-1-12
A fluoroketone clean agent, the alternative agent offered in Firessense cylinders.
Direct low-pressure system
A system in which the detection tube itself bursts at the fire and becomes the discharge point.
LPCB
The Loss Prevention Certification Board, which approves fire protection products; Firessense is LPCB approved to LPS 1666.
UL Listed
Tested and listed by UL for a defined use; the Synergy Kitchen Fire Suppression System is UL Listed.
SBC 801
The Saudi Fire Code, part of the Saudi Building Code, used in Civil Defense fire safety approvals.
Get a quotation

Send a photo of the hood or panel. We’ll come back with the system.

City, hazard type and one photograph are enough to start. Add the appliance list, panel sizes, drawings or BOQ when you have them.

Related SolidDrops pages

Reviewed by the SolidDrops technical team · Last updated 22 October 2026 · Technical data and product photographs from Swastik Synergy Engineering Pvt. Ltd.